MSI A320M PRO-VD/S V2: USB Device Overcurrent Detected. System Will Shut Down in 15 Seconds – 100% Repair Solution


MSI A320M PRO-VD/S V2: USB Device Overcurrent Status Detected. The system will shut down in 15 seconds to avoid damage to the motherboard. This is a common problem, and I will show you how to fix it easily and for free.

Step-by-Step Guide: Fix MSI A320M PRO-VD/S V2USB Device Overcurrent Status Detected

1. Check the 5V Fuse: Inspect all four USB 5V fuse inputs and outputs to ensure they are providing 5V. If 5V is not present, replace the fuse.

2. Verify Voltage After Fuse Replacement: If the voltage is still not 5V after replacing the fuse, remove the ESD (Electrostatic Discharge) protection component.

3. Check N-Channel MOSFET: If all USB 5V fuses show the correct voltage, proceed to check the N-Channel MOSFET. Measure the voltage at pin D2, which should be 3.3V.

4. Address MOSFET Issues: If the voltage at pin D2 is not 3.3V, remove the MOSFET. If the voltage does not stabilize after removal, use a jumper to supply 3.3V from another source.

By following these steps, you can resolve the overcurrent issue and prevent the system from shutting down. This method has a 100% success rate in fixing this problem.